Replaces MIL-STD-461G. Radar, radio, platform power and neighbouring electronics share very little space on vehicles, aircraft and ships – every unit has to work there without being disturbed and without disturbing others. The U.S. military standard MIL-STD-461H of April 2026 defines how the emissions and susceptibility of equipment and subsystems are verified: conducted via power, signal and antenna leads, and radiated via electric and magnetic fields. EDAG Testing performs the tests to MIL-STD-461H and to the previous edition MIL-STD-461G individually or as a complete test sequence.

You can request the complete testing standard or individual tests from the standard.

Configurations:

Please enter any additional information here:

Please provide additional information here (required scope of testing, component, dimensions, quantity, etc.).
Drag & drop files here (Max. 1 file(s), max. 10 MB per file)
Share your configuration
Product Quantity: Enter the desired amount or use the buttons to increase or decrease the quantity.

Scope of testing to MIL-STD-461H (replaces MIL-STD-461G)

MIL-STD-461H specifies 19 requirements, grouped into conducted emissions (CE), conducted susceptibility (CS), radiated emissions (RE) and radiated susceptibility (RS); section numbers 5.4 to 5.22 are unchanged from MIL-STD-461G. Which requirements apply depends on the platform and installation location of the equipment. We perform each test individually or as a complete test sequence to your specification.

↓Conducted emissions (CE)↓Conducted susceptibility (CS)↓Lightning and ESD↓Radiated emissions (RE)↓Radiated susceptibility (RS)↓Contact

Conducted emissions to MIL-STD-461H (CE101 to CE106)

Every electronic unit emits interference through its power leads and antenna ports that can affect other equipment on the same platform. The CE requirements limit these conducted emissions – from low-frequency interference currents to spurious emissions at transmitter antenna outputs.

CE101
Sec. 5.4
Conducted Emissions, Audio Frequency Currents, Power Leads: Measures the low-frequency interference currents that the equipment feeds back into the platform power system through its power leads, for example from power supplies, switching regulators or motors. The limits protect other loads on the same supply from power distortion.
CE102
Sec. 5.5
Conducted Emissions, Radio Frequency Potential, Power Leads: Measures radio frequency interference voltages on the power leads using a line impedance stabilization network (LISN). The requirement protects receivers and sensitive equipment connected to the same power distribution.
CE106
Sec. 5.6
Conducted Emissions, Antenna Port: Measures emissions at the antenna port of transmitters, receivers and amplifiers, in transmit mode as well as in receive or standby mode. Evaluates harmonics and spurious emissions that would otherwise be radiated by the antenna.

↑ Back to overview

Conducted susceptibility to MIL-STD-461H (CS101 to CS116)

Power systems on military platforms carry ripple, coupled RF currents and switching transients. The CS requirements demonstrate that equipment tolerates interference on power leads, cable bundles, structure and antenna ports without degraded performance; CS103 to CS105 are specific to receivers.

CS101
Sec. 5.7
Conducted Susceptibility, Power Leads: Tests immunity to low-frequency ripple and harmonics superimposed on the supply voltage of the platform power system. Since MIL-STD-461H, a differential probe and a ripple detection transducer are permitted as alternatives to the isolation transformer for the measurement.
CS103
Sec. 5.8
Conducted Susceptibility, Antenna Port, Intermodulation: Tests receivers at the antenna port for intermodulation: two out-of-band interfering signals must not produce mixing products in the receiver that degrade the wanted signal.
CS104
Sec. 5.9
Conducted Susceptibility, Antenna Port, Rejection of Undesired Signals: Tests how well a receiver rejects individual undesired signals outside its receive channel. The interfering signal is applied together with the wanted signal, and the test checks whether reception quality is maintained.
CS105
Sec. 5.10
Conducted Susceptibility, Antenna Port, Cross Modulation: Tests receivers for cross-modulation: a modulated out-of-band interfering signal must not transfer its modulation onto the wanted signal.
CS109
Sec. 5.11
Conducted Susceptibility, Structure Current: Tests immunity to currents flowing through the structure or chassis of the equipment. The requirement addresses very sensitive equipment, mainly on naval platforms, whose operation can be disturbed by currents in the structure.
CS114
Sec. 5.12
Conducted Susceptibility, Bulk Cable Injection: An injection probe couples RF interference current into cable bundles and power leads (bulk current injection). This simulates how electromagnetic fields induce currents on the equipment's cabling in service.
CS115
Sec. 5.13
Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation: Short, fast-rising pulses are coupled into cable bundles via an injection probe. The test simulates fast transients caused by switching actions on the platform.
CS116
Sec. 5.14
Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads: Damped sinusoidal transients are coupled into cable bundles and individual power leads. They simulate the ringing waveforms excited in platform wiring by switching actions, lightning or electromagnetic pulses.

↑ Back to overview

Lightning transients and ESD to MIL-STD-461H (CS117, CS118)

MIL-STD-461G introduced two requirements for high-energy single events: indirect lightning effects on the wiring and electrostatic discharge from personnel. Both demonstrate that interfaces, enclosures and controls withstand such events without damage.

CS117
Sec. 5.15
Conducted Susceptibility, Lightning Induced Transients, Cables and Power Leads: Simulates the indirect effects of a lightning strike on the platform: the transients induced in the wiring are coupled into cable bundles and power leads. The test demonstrates that interfaces and power inputs withstand the stress without damage or loss of function.
CS118
Sec. 5.16
Personnel Borne Electrostatic Discharge: Electrostatic discharges are applied to points touched during operation and maintenance, such as enclosures, controls and connectors. The test demonstrates that discharges from personnel cause no damage or malfunction.

↑ Back to overview

Radiated emissions to MIL-STD-461H (RE101 to RE103)

Fields radiated by equipment and cables can interfere with nearby antennas, receivers and sensors. The RE requirements measure magnetic and electric fields in a defined test setup as well as transmitter spurious emissions radiated by the antenna. For all emission measurements, MIL-STD-461H requires finer receiver frequency steps than the previous edition.

RE101
Sec. 5.17
Radiated Emissions, Magnetic Field: Measures the low-frequency magnetic fields emanating from the equipment and its cables at close range using a loop sensor. The limits protect magnetically sensitive equipment and sensors nearby.
RE102
Sec. 5.18
Radiated Emissions, Electric Field: Measures the electric fields radiated by the equipment and its cabling in a shielded, absorber-lined enclosure. The limits protect the platform's antennas and receivers; MIL-STD-461H now explicitly defines the orientation of the measurement antenna.
RE103
Sec. 5.19
Radiated Emissions, Antenna Spurious and Harmonic Outputs: Measures harmonics and spurious emissions of transmitters as radiated by the antenna. The test serves as an alternative to CE106, for example when the antenna port is not accessible or the antenna is integral to the equipment.

↑ Back to overview

Radiated susceptibility to MIL-STD-461H (RS101 to RS105)

Strong fields from radar and radio systems, magnetic fields from power distribution and electromagnetic pulses act on equipment in service. The RS requirements expose the test item to these fields and demonstrate that it continues to operate without malfunction.

RS101
Sec. 5.20
Radiated Susceptibility, Magnetic Field: Tests immunity to low-frequency magnetic fields generated with a radiating loop or a Helmholtz coil. This demonstrates that strong magnetic fields from nearby busbars, transformers or drives do not cause malfunctions.
RS103
Sec. 5.21
Radiated Susceptibility, Electric Field: The test item is exposed to electric fields such as those generated by transmitters, radar and radio systems, in an absorber-lined enclosure. For higher frequencies the standard alternatively permits testing in a reverberation chamber.
RS105
Sec. 5.22
Radiated Susceptibility, Transient Electromagnetic Field: Tests immunity to a very fast, high-energy transient field that simulates an electromagnetic pulse (EMP). The requirement mainly concerns equipment installed outside shielded areas of the platform.