Skip to main content Skip to search Skip to main navigation
Menu
Tests

Defence

Our testing expertise spans a wide range of industries and also includes the demanding defence sector. For this area, we offer specialised testing services in accordance with AECTP, MIL, and DO standards, where maximum reliability is the top priority. This includes development-phase testing in accordance with these standards, as well as qualification testing for safety-critical systems. These services are complemented by reliability analyses and service life predictions, providing a sound basis for assessing the long-term behaviour of the systems under test.

16 Products
AECTP-300

AECTP-300

Scope of testing to AECTP-300

AECTP-300 brings together the climatic test methods of NATO's AECTP series: an introductory part sets out general test conditions and tolerances, and Methods 302 to 319 describe the individual tests. Test parameters, durations and sequence are derived for each programme from the environmental conditions in AECTP-200 and the equipment's service profile. We perform each method individually or as a complete test sequence to your specification.

↓Temperature↓Solar, humidity, water↓Corrosion and fluids↓Pressure, dust, atmosphere↓Combined tests↓Contact

Temperature tests to AECTP-300 (302 to 304, 315)

Military equipment is deployed in deserts as well as arctic regions and sometimes moves between extreme temperatures within minutes. The temperature methods test storage, operation and handling at the limits of the climatic zones the equipment is designed for.

302High Temperature: Storage and operation at high temperatures as found in hot climates, in parked vehicles or in heated containers. Demonstrates operation, material behaviour and dimensional stability at the upper temperature limit.
303Low Temperature: Storage, operation and handling in cold climates. Checks whether the equipment starts after cold exposure and remains operable, and whether plastics, elastomers and lubricants retain their properties.
304Thermal Shock: Rapid transition between widely different temperatures, for example when moving from a heated shelter into arctic cold or during air transport. The test reveals cracks, leaks and joint failures caused by uneven thermal expansion.
315Freeze/Thaw: Repeated cycling through the freezing point, causing moisture in gaps, seals and cavities to freeze and thaw. Evaluates damage from ice formation and operation after cycling.

↑ Back to overview

Solar, humidity and water tests to AECTP-300 (305 to 307, 310, 311)

Sunlight, tropical humidity, rain, ice and water act on enclosures and seals continuously in the field. These methods demonstrate that materials remain stable and that no water enters the equipment.

305Solar Radiation: Irradiation with simulated sunlight that reproduces both the heating of the test item and the ageing of surfaces by UV radiation. Evaluates thermal behaviour, colour and material changes and operation.
306Humid Heat: Exposure to a warm, humid atmosphere, partly with temperature cycles, as found in tropical regions. Checks moisture absorption, corrosion, insulation behaviour and operation after exposure.
307Immersion: Partial or complete immersion in water, for example during river crossings or flooding. Demonstrates that no water enters and that the equipment works afterwards.
310Rain/Watertightness: Exposure to wind-driven rain, dripping water or water jets. Checks the watertightness of enclosures, covers and connectors and operation during and after exposure.
311Icing: Ice accretion from freezing rain or water spray. Checks whether moving parts, controls and antennas remain functional under the ice layer.

↑ Back to overview

Corrosion, fluid and mould tests to AECTP-300 (308, 309, 314, 319)

Salt-laden air, acidic atmospheres, operating fluids and mould attack materials slowly but persistently. The methods in this group evaluate corrosion protection, fluid resistance and the susceptibility of organic materials to mould.

308Mould Growth: Extended exposure to mould spores in a warm, humid environment. The test shows whether materials, coatings or contamination promote mould growth and whether operation or insulation suffers as a result.
309Salt Fog: Exposure to salt fog as found in coastal and maritime environments. Evaluates corrosion of metals, contacts and fasteners and the protection provided by coatings.
314Contamination by Fluids: Contact with operating fluids such as fuels, oils, hydraulic fluids and cleaning agents. Checks swelling, discoloration, coating detachment and operation after exposure.
319Acidic Atmosphere: Exposure to an acidic atmosphere such as found in industrial areas or near combustion exhaust. Evaluates corrosion and the resistance of surfaces and protective coatings.

↑ Back to overview

Pressure, dust and atmosphere tests to AECTP-300 (312, 313, 316)

Air transport, high-altitude operation, desert dust and fuel-laden surroundings place particular demands on sealing and safety. AECTP-300 covers natural environments up to an altitude of 30,000 m; beyond that it refers to space standards.

312Low Pressure: Storage and operation at reduced air pressure, for example during air transport in unpressurised cargo holds or in high mountain areas. Evaluates sealing, enclosure deformation and malfunctions due to reduced heat dissipation.
313Sand and Dust: Exposure to blowing dust and sand as found in deserts, on unpaved tracks or in helicopter rotor downwash. Checks particle ingress, abrasion and malfunctions of ventilation, connectors and mechanisms.
316Explosive Atmosphere: Operation in an ignitable mixture of fuel vapour and air. Demonstrates that the equipment does not cause ignition, or that an ignition inside the enclosure does not propagate to the outside.

↑ Back to overview

Combined tests to AECTP-300 (317, 318)

In service, temperature, humidity, air pressure and vibration act simultaneously. The combined methods superimpose these stresses and reveal interactions that separate individual tests would miss.

317Temperature/Humidity/Altitude: Combined exposure to temperature, humidity and low air pressure, mainly for equipment in aircraft. The test reveals effects that only occur in combination, such as condensation during descent.
318Vibration/Temperature/Humidity/Altitude: Superimposes vibration on temperature, humidity and altitude, as experienced by airborne equipment and aircraft stores. This reveals failures that neither climatic nor vibration testing alone would show.

↑ Back to overview

AECTP-400

AECTP-400

Scope of testing to AECTP-400

AECTP-400 contains the mechanical test methods of NATO's AECTP series. In the current Edition D of November 2019, Method 400 sets out the general test conditions, and several former methods have been merged: handling and SRS shock into Method 403, and tiedown, lifting, stacking, bending and racking into Method 424. We perform each method individually or as a complete test sequence to your specification.

↓Vibration and acoustics↓Shock↓Acceleration and motion↓Transport and storage↓Contact

Vibration and acoustic tests to AECTP-400 (401, 402, 413, 420, 421)

Tracks, rotors, engines and airflow excite equipment throughout its service life. These methods reproduce the excitation mechanically, acoustically or in combination and demonstrate that structure, mounting and electronics withstand the sustained loading.

401Vibration: Vibration testing with sine, random or mixed excitation reproducing transport and service loads on wheeled and tracked vehicles, aircraft and ships. Test severities are derived from measured data or the environments described in AECTP-200.
402Acoustic Noise: Exposure to high sound pressure levels in a reverberation chamber or progressive wave tube, as found near jet engines, in weapon bays or on missiles. Checks structural fatigue and malfunctions caused by acoustically induced vibration.
413Acoustic Noise Combined with Temperature and Vibration: Superimposes acoustic excitation, vibration and temperature, mainly for missiles and external stores carried in flight. The combination reveals failures that do not occur in separate tests.
420Buffet Vibration: Vibration caused by flow separation and vortices on aircraft structures, for example on the tail during high angle-of-attack manoeuvres. Checks the fatigue strength of equipment in the affected areas.
421Multi-Exciter Vibration and Shock Testing: Vibration and shock testing with multiple exciters for large test items or for excitation in more than one mechanical degree of freedom. This produces realistic motion that a single shaker cannot reproduce.

↑ Back to overview

Shock tests to AECTP-400 (403, 405, 415, 419, 422)

Shocks arise from handling and transport, the platform's own gunfire, pyrotechnic devices, underwater explosions and ballistic impact. The shock methods therefore range from classical waveforms to very severe, high-frequency loads and demonstrate that equipment remains operational afterwards.

403Shock Testing: Shock loads from handling, transport and service, reproduced with classical waveforms such as half-sine and sawtooth or via a shock response spectrum (SRS). Since Edition D the method also covers the former methods for handling shock and SRS shock.
Former methods: 403 Classical Waveform Shock · 414 Handling · 417 SRS Shock
405Gunfire: Shock and vibration caused by firing the platform's own weapons, such as aircraft guns or weapon systems on vehicles and ships. Checks whether nearby equipment withstands the repeated excitation without damage or loss of function.
415Pyroshock: Very short, high-frequency shock waves from firing pyrotechnic devices, for example during stage separation, store release or activation of escape systems. Checks the robustness of sensitive electronics close to the source.
419UNDEX: Shock loading from underwater explosions, as may affect ships and submarines in service. Demonstrates that equipment installed on board survives the shock and remains operational.
422Ballistic Shock: Very high, short-duration shock when projectiles or explosive devices hit armoured vehicles. Checks whether equipment mounted in the vehicle withstands this load without damage or loss of function.

↑ Back to overview

Acceleration and motion tests to AECTP-400 (404, 418)

Besides vibration and shock, equipment is subject to sustained acceleration and large-scale movements of its carrier platform. These methods test strength, mounting and operation under such quasi-static and low-frequency loads.

404Constant Acceleration: Steady acceleration on a centrifuge, as occurs during flight manoeuvres, missile launch or in rotating systems. Checks the strength of structure and mountings and operation under load.
418Motion Platform: Testing on a motion platform that reproduces large-amplitude, low-frequency movements of a carrier platform. Evaluates operation and mounting of the test item under these movements.

↑ Back to overview

Transport and storage tests to AECTP-400 (406, 408, 416, 424)

Before equipment is deployed, it is stored, stacked, tied down, lifted by crane and transported by road and rail. These methods demonstrate that equipment, packaging and transit containers withstand the resulting loads without damage.

406Loose Cargo: Unsecured transport on a cargo bed, where the test item bounces, slides and impacts against restraints. The test is performed on a package tester with circular motion and evaluates enclosure, packaging and operation.
408Large Assembly Transport: Transport of large assemblies and shelters on the intended vehicle over defined test courses, since their size usually rules out testing on a vibration table. Evaluates mounting, structure and operation after the run.
416Rail Impact: Coupling impacts during shunting of railcars in rail transport. Evaluates the strength of the test item, its mountings and its tie-down.
424Storage and Transit: Since Edition D, combines the mechanical loads from storage, handling and transit, including tiedown, lifting, stacking, bending and racking of materiel and transit containers. Demonstrates that equipment, containers and attachment points withstand these loads without permanent damage.
Former methods: 407 Materiel Tiedown · 409 Materiel Lifting · 410 Materiel Stacking · 411 Materiel Bending · 412 Materiel Racking

↑ Back to overview

AECTP-500

AECTP-500

Scope of testing to AECTP-500 (Category 501)

Category 501 of AECTP-500 specifies the EMC tests for equipment and subsystems, which are normally performed in a screened room. The 25 tests are derived from MIL-STD-461 and the British DEF STAN 59-411 and are grouped into conducted and radiated emissions (NCE, NRE) and susceptibility (NCS, NRS). Which tests apply depends on the application and platform; some selection rules are set by the procuring nation. We perform each test individually or as a complete test sequence to your specification.

↓Conducted emissions (NCE)↓Conducted susceptibility (NCS)↓Radiated emissions (NRE)↓Radiated susceptibility (NRS)↓Contact

Conducted emissions to AECTP-500 (NCE01 to NCE05)

Every unit emits interference into the platform supply and wiring through its power, signal and antenna leads. The NCE tests limit these emissions in the frequency and time domains; three tests come from MIL-STD-461 and two from the British DEF STAN 59-411.

NCE01
Sec. 6.4
Power Leads, 30 Hz to 10 kHz: Measures low-frequency interference currents fed back onto the supply leads, for example by rectifiers, inverters or switched-mode power supplies. This prevents such currents from distorting the supply of other onboard loads.
Derived from: MIL-STD-461 (cf. CE101)
NCE02
Sec. 6.5
Power Leads, 10 kHz to 10 MHz: Measures radio-frequency interference voltages on the supply leads via a line impedance stabilisation network. The limits protect sensitive receivers powered from the same platform supply.
Derived from: MIL-STD-461 (cf. CE102)
NCE03
Sec. 6.6
Antenna Terminal, 10 kHz to 40 GHz: Measures spurious emissions and harmonics at the antenna terminal of transmitters and receivers. The measurement is taken directly at the terminal, before the interference can be radiated by the antenna.
Derived from: MIL-STD-461 (cf. CE106)
NCE04
Sec. 6.7
Exported Transients on Power Leads: Measures switching transients that the equipment puts onto its supply leads when switched on and off or during load changes. The test ensures that such spikes do not affect other loads on the same supply.
Derived from: DEF STAN 59-411
NCE05
Sec. 6.8
Power, Control & Signal Leads, 30 Hz to 150 MHz: Measures interference currents on power, control and signal leads over a wide frequency range in one measurement. Where NCE05 is performed, NCE01 and NCE02 are not required.
Derived from: DEF STAN 59-411

↑ Back to overview

Conducted susceptibility to AECTP-500 (NCS01 to NCS13)

With 13 tests, conducted susceptibility is the largest group. It ranges from low-frequency ripple and bulk current injection to transients, lightning, ESD and the receiver tests at the antenna port; NCS10 and NCS11 are national requirements of the United Kingdom.

NCS01
Sec. 6.9
Power Leads, 30 Hz to 150 kHz: Tests immunity to low-frequency AC components on the supply leads, as generated by generators and large loads. The equipment must operate without degradation while ripple is superimposed.
Derived from: MIL-STD-461 (cf. CS101)
NCS02
Sec. 6.10
Control & Signal Leads, 20 Hz to 50 kHz: Tests the immunity of control and signal leads to low-frequency interference coupled from adjacent cables. Evaluates whether signals and control functions remain unaffected.
Derived from: DEF STAN 59-411
NCS03
Sec. 6.11
Antenna Port, Intermodulation, 15 kHz to 10 GHz: Evaluates the intermodulation performance of receivers. Two signals outside the receive band are applied simultaneously at the antenna port; no interfering mixing product may appear in the wanted channel.
Derived from: MIL-STD-461 (cf. CS103)
NCS04
Sec. 6.12
Antenna Port, Rejection of Undesired Signals, 30 Hz to 20 GHz: Evaluates receiver selectivity against individual signals outside the wanted channel. Checks whether a strong unwanted signal degrades reception of the wanted signal.
Derived from: MIL-STD-461 (cf. CS104)
NCS05
Sec. 6.13
Antenna Port, Cross Modulation, 30 Hz to 20 GHz: Evaluates the cross-modulation performance of receivers. A modulated signal adjacent to the wanted channel must not transfer its modulation onto the received signal.
Derived from: MIL-STD-461 (cf. CS105)
NCS06
Sec. 6.14
Structure Current, 60 Hz to 100 kHz: Injects interference currents through the equipment structure, as caused by potential differences in the platform structure. The test addresses equipment with very sensitive low-frequency inputs.
Derived from: MIL-STD-461 (cf. CS109)
NCS07
Sec. 6.15
Bulk Current Injection, 10 kHz to 200 MHz: Couples RF currents into cable bundles via a current probe, reproducing the effect of external fields on the cabling. Checks across the whole frequency range whether equipment functions are disturbed.
Derived from: MIL-STD-461 (cf. CS114)
NCS08
Sec. 6.16
Bulk Current Injection, Impulse Excitation: Couples short pulses into cable bundles via a current probe, reproducing the effect of fast switching transients on the cabling.
Derived from: MIL-STD-461 (cf. CS115)
NCS09
Sec. 6.17
Damped Sinusoidal Transients, Cables and Power Leads, 10 kHz to 100 MHz: Damped sinusoidal waveforms are applied to cable bundles and individual supply leads. They correspond to the ringing that lightning, EMP or switching excites in platform wiring.
Derived from: MIL-STD-461 (cf. CS116)
NCS10
Sec. 6.18
Imported Lightning Transient (Aircraft/Weapons): Reproduces the transients coupled onto the wiring by a lightning strike on aircraft and weapon systems. The test is a national requirement of the United Kingdom.
Derived from: DEF STAN 59-411
NCS11
Sec. 6.19
Imported Low Frequency on Power Leads (Ships): Tests shipborne equipment for low-frequency interference coupled in via the supply leads. Like NCS10, it is a national requirement of the United Kingdom.
Derived from: DEF STAN 59-411
NCS12
Sec. 6.20
Electrostatic Discharge: Electrostatic discharges are applied to accessible points of the equipment, as occur during operation and maintenance. Demonstrates that neither damage nor malfunction results.
Derived from: DEF STAN 59-411
NCS13
Sec. 6.21
Transient Power Leads: Short voltage transients are applied to the supply leads, as caused by load switching on the platform supply. The equipment must remain undamaged and operational.
Derived from: MIL-STD-461 (cf. CS106, edition F)

↑ Back to overview

Radiated emissions to AECTP-500 (NRE01 to NRE03)

Radiated magnetic and electric fields can interfere with nearby antennas, receivers and sensors. The NRE tests measure these fields in a screened room and capture transmitter spurious outputs.

NRE01
Sec. 6.22
Magnetic Field, 30 Hz to 100 kHz: Measures the low-frequency magnetic near field of the equipment and its cabling. The limits protect sensors and receivers that are sensitive to magnetic fields.
Derived from: MIL-STD-461 (cf. RE101)
NRE02
Sec. 6.23
Electric Field, 10 kHz to 18 GHz: Measures the electric fields radiated by the equipment and its cabling in a screened room. This limits interference with antennas and receivers on the same platform.
Derived from: MIL-STD-461 (cf. RE102)
NRE03
Sec. 6.24
Antenna Spurious and Harmonic Outputs, 10 kHz to 40 GHz: Measures the harmonics and spurious outputs of transmitters radiated by their antenna. It complements the antenna terminal measurement (NCE03), for example for integral antennas.
Derived from: MIL-STD-461 (cf. RE103)

↑ Back to overview

Radiated susceptibility to AECTP-500 (NRS01 to NRS04)

The NRS tests expose the equipment to magnetic fields, electric fields and transient field pulses as found on military platforms. NRS04 adds static magnetic fields for naval platforms to the tests known from MIL-STD-461.

NRS01
Sec. 6.25
Magnetic Field, 30 Hz to 100 kHz: Exposes the equipment to low-frequency magnetic fields generated with a radiating loop or Helmholtz coil. Checks whether magnetic fields from power distribution and drives cause malfunctions.
Derived from: MIL-STD-461 (cf. RS101)
NRS02
Sec. 6.26
Electric Field, 2 MHz to 40 GHz: Irradiates the equipment with electric fields over a wide frequency range, as generated by radio and radar systems. Demonstrates interference-free operation in the electromagnetic environment of the platform.
Derived from: MIL-STD-461 (cf. RS103) and DEF STAN 59-411
NRS03
Sec. 6.27
Transient Electromagnetic Field: Tests immunity to a fast, high-energy field pulse simulating a nuclear electromagnetic pulse. It mainly concerns equipment outside shielded areas.
Derived from: MIL-STD-461 (cf. RS105)
NRS04
Sec. 6.28
Magnetic Field (DC): Tests immunity to static magnetic fields. The requirement applies to equipment on platforms fitted with a degaussing system or subject to deperming.
Derived from: DEF STAN 59-411

↑ Back to overview

MiL 461G

MiL 461G

MiL 461G
MIL-STD-461H

MIL-STD-461H

Scope of testing to MIL-STD-461H (replaces MIL-STD-461G)

MIL-STD-461H specifies 19 requirements, grouped into conducted emissions (CE), conducted susceptibility (CS), radiated emissions (RE) and radiated susceptibility (RS); section numbers 5.4 to 5.22 are unchanged from MIL-STD-461G. Which requirements apply depends on the platform and installation location of the equipment. We perform each test individually or as a complete test sequence to your specification.

↓Conducted emissions (CE)↓Conducted susceptibility (CS)↓Lightning and ESD↓Radiated emissions (RE)↓Radiated susceptibility (RS)↓Contact

Conducted emissions to MIL-STD-461H (CE101 to CE106)

Every electronic unit emits interference through its power leads and antenna ports that can affect other equipment on the same platform. The CE requirements limit these conducted emissions – from low-frequency interference currents to spurious emissions at transmitter antenna outputs.

CE101
Sec. 5.4
Conducted Emissions, Audio Frequency Currents, Power Leads: Measures the low-frequency interference currents that the equipment feeds back into the platform power system through its power leads, for example from power supplies, switching regulators or motors. The limits protect other loads on the same supply from power distortion.
CE102
Sec. 5.5
Conducted Emissions, Radio Frequency Potential, Power Leads: Measures radio frequency interference voltages on the power leads using a line impedance stabilization network (LISN). The requirement protects receivers and sensitive equipment connected to the same power distribution.
CE106
Sec. 5.6
Conducted Emissions, Antenna Port: Measures emissions at the antenna port of transmitters, receivers and amplifiers, in transmit mode as well as in receive or standby mode. Evaluates harmonics and spurious emissions that would otherwise be radiated by the antenna.

↑ Back to overview

Conducted susceptibility to MIL-STD-461H (CS101 to CS116)

Power systems on military platforms carry ripple, coupled RF currents and switching transients. The CS requirements demonstrate that equipment tolerates interference on power leads, cable bundles, structure and antenna ports without degraded performance; CS103 to CS105 are specific to receivers.

CS101
Sec. 5.7
Conducted Susceptibility, Power Leads: Tests immunity to low-frequency ripple and harmonics superimposed on the supply voltage of the platform power system. Since MIL-STD-461H, a differential probe and a ripple detection transducer are permitted as alternatives to the isolation transformer for the measurement.
CS103
Sec. 5.8
Conducted Susceptibility, Antenna Port, Intermodulation: Tests receivers at the antenna port for intermodulation: two out-of-band interfering signals must not produce mixing products in the receiver that degrade the wanted signal.
CS104
Sec. 5.9
Conducted Susceptibility, Antenna Port, Rejection of Undesired Signals: Tests how well a receiver rejects individual undesired signals outside its receive channel. The interfering signal is applied together with the wanted signal, and the test checks whether reception quality is maintained.
CS105
Sec. 5.10
Conducted Susceptibility, Antenna Port, Cross Modulation: Tests receivers for cross-modulation: a modulated out-of-band interfering signal must not transfer its modulation onto the wanted signal.
CS109
Sec. 5.11
Conducted Susceptibility, Structure Current: Tests immunity to currents flowing through the structure or chassis of the equipment. The requirement addresses very sensitive equipment, mainly on naval platforms, whose operation can be disturbed by currents in the structure.
CS114
Sec. 5.12
Conducted Susceptibility, Bulk Cable Injection: An injection probe couples RF interference current into cable bundles and power leads (bulk current injection). This simulates how electromagnetic fields induce currents on the equipment's cabling in service.
CS115
Sec. 5.13
Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation: Short, fast-rising pulses are coupled into cable bundles via an injection probe. The test simulates fast transients caused by switching actions on the platform.
CS116
Sec. 5.14
Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads: Damped sinusoidal transients are coupled into cable bundles and individual power leads. They simulate the ringing waveforms excited in platform wiring by switching actions, lightning or electromagnetic pulses.

↑ Back to overview

Lightning transients and ESD to MIL-STD-461H (CS117, CS118)

MIL-STD-461G introduced two requirements for high-energy single events: indirect lightning effects on the wiring and electrostatic discharge from personnel. Both demonstrate that interfaces, enclosures and controls withstand such events without damage.

CS117
Sec. 5.15
Conducted Susceptibility, Lightning Induced Transients, Cables and Power Leads: Simulates the indirect effects of a lightning strike on the platform: the transients induced in the wiring are coupled into cable bundles and power leads. The test demonstrates that interfaces and power inputs withstand the stress without damage or loss of function.
CS118
Sec. 5.16
Personnel Borne Electrostatic Discharge: Electrostatic discharges are applied to points touched during operation and maintenance, such as enclosures, controls and connectors. The test demonstrates that discharges from personnel cause no damage or malfunction.

↑ Back to overview

Radiated emissions to MIL-STD-461H (RE101 to RE103)

Fields radiated by equipment and cables can interfere with nearby antennas, receivers and sensors. The RE requirements measure magnetic and electric fields in a defined test setup as well as transmitter spurious emissions radiated by the antenna. For all emission measurements, MIL-STD-461H requires finer receiver frequency steps than the previous edition.

RE101
Sec. 5.17
Radiated Emissions, Magnetic Field: Measures the low-frequency magnetic fields emanating from the equipment and its cables at close range using a loop sensor. The limits protect magnetically sensitive equipment and sensors nearby.
RE102
Sec. 5.18
Radiated Emissions, Electric Field: Measures the electric fields radiated by the equipment and its cabling in a shielded, absorber-lined enclosure. The limits protect the platform's antennas and receivers; MIL-STD-461H now explicitly defines the orientation of the measurement antenna.
RE103
Sec. 5.19
Radiated Emissions, Antenna Spurious and Harmonic Outputs: Measures harmonics and spurious emissions of transmitters as radiated by the antenna. The test serves as an alternative to CE106, for example when the antenna port is not accessible or the antenna is integral to the equipment.

↑ Back to overview

Radiated susceptibility to MIL-STD-461H (RS101 to RS105)

Strong fields from radar and radio systems, magnetic fields from power distribution and electromagnetic pulses act on equipment in service. The RS requirements expose the test item to these fields and demonstrate that it continues to operate without malfunction.

RS101
Sec. 5.20
Radiated Susceptibility, Magnetic Field: Tests immunity to low-frequency magnetic fields generated with a radiating loop or a Helmholtz coil. This demonstrates that strong magnetic fields from nearby busbars, transformers or drives do not cause malfunctions.
RS103
Sec. 5.21
Radiated Susceptibility, Electric Field: The test item is exposed to electric fields such as those generated by transmitters, radar and radio systems, in an absorber-lined enclosure. For higher frequencies the standard alternatively permits testing in a reverberation chamber.
RS105
Sec. 5.22
Radiated Susceptibility, Transient Electromagnetic Field: Tests immunity to a very fast, high-energy transient field that simulates an electromagnetic pulse (EMP). The requirement mainly concerns equipment installed outside shielded areas of the platform.

↑ Back to overview

MIL-STD-810H

MIL-STD-810H

Scope of testing to MIL-STD-810H

Part Two of MIL-STD-810H contains 29 laboratory test methods numbered 500 to 528; the digit after the point indicates the revision of the method (514.8 is the eighth revision of Method 514). Which methods, procedures and severities apply is determined by tailoring them to the item's life cycle environmental profile. We perform each method individually or as a complete test sequence to your specification.

↓Temperature and pressure↓Weather, water, dust↓Fluids and corrosion↓Vibration and shock↓Combined tests↓Contact

Temperature and pressure tests to MIL-STD-810H (500.6 to 503.7, 521.4, 524.1)

Low pressure in an aircraft cargo hold, heat on the flight line, a cold start in freezing conditions: temperature and air pressure affect materials, seals, lubricants and electronics. The methods in this group demonstrate that the test item withstands storage, transport and operation under extreme temperatures, rapid temperature changes, icing and low pressure without loss of function. Test limits are taken from the life cycle environmental profile or from the climatic data in Part Three of the standard.

500.6Low Pressure (Altitude): Testing under reduced air pressure as found in air transport, operation at high altitude or rapid decompression. Evaluates enclosure sealing and deformation, arcing and overheating caused by reduced air cooling, and operation during and after exposure.
501.7High Temperature: Storage and operation at high ambient temperatures or under heat build-up in parked vehicles, enclosures or direct sunlight. Separate storage and operation procedures reveal deformation, ageing, softening of materials and malfunctions at the upper temperature limit.
502.7Low Temperature: Storage, operation and manipulation in the cold. Demonstrates cold start, operation and handling when plastics become brittle, lubricants thicken and seals lose elasticity.
503.7Temperature Shock: Sudden changes in ambient temperature, for example between an air-conditioned interior and a hot or cold outdoor environment. Checks for cracks, loosened joints, leaking seals and solder joint damage caused by the different thermal expansion of materials.
521.4Icing/Freezing Rain: Ice accretion on the surface of the test item from freezing rain or water spray. Evaluates whether moving parts, closures, antennas and controls still work under the ice layer and whether de-icing equipment is effective.
524.1Freeze/Thaw: Temperature cycling through the freezing point, causing absorbed or condensed moisture to freeze and thaw. The test reveals damage from the expansion of ice, for example to seals, enclosure joints, circuit boards and optical components.

↑ Back to overview

Weather, water and dust tests to MIL-STD-810H (505.7 to 507.6, 510.7, 512.6)

Sunlight, rain, humidity, sand and water attack surfaces, seals and electronics in different ways. These methods check whether enclosures and seals protect the test item from water and dust ingress and whether materials remain stable under solar radiation and damp heat – in outdoor use as well as during storage and transport.

505.7Solar Radiation (Sunshine): Irradiation with a simulated solar spectrum for equipment used outdoors. A cycling procedure reproduces solar heating, a steady-state procedure the photodegradation of plastics, paints, rubber and markings.
506.6Rain: Exposure to blowing rain, exaggerated water spray or dripping water. Checks how well enclosures, covers and seals keep water out and whether the test item works during and after exposure.
507.6Humidity: Cyclic exposure to a warm, humid atmosphere that reproduces natural or induced humidity conditions. Evaluates corrosion, moisture absorption of materials, insulation behaviour and malfunctions caused by condensation.
510.7Sand and Dust: Exposure to blowing dust and blowing sand in separate procedures. Checks particle ingress into enclosures and connectors, abrasion of surfaces and optics, and malfunctions from clogged ventilation and jammed mechanisms.
512.6Immersion: Partial or complete immersion in water, as during fording or flooding. Demonstrates the watertightness of the enclosure and operation after immersion.

↑ Back to overview

Fluid, corrosion and atmosphere tests to MIL-STD-810H (504.3, 508.8, 509.8, 511.7, 518.2)

Operating fluids, salt-laden air, acids and microorganisms often act slowly: they attack coatings, corrode contacts or degrade organic materials. The group also includes testing in an explosive atmosphere, which demonstrates safe operation in fuel-laden surroundings.

504.3Contamination by Fluids: Temporary contact with operating fluids such as fuels, hydraulic fluids, lubricants and cleaning agents, as during refuelling, maintenance or leaks. Evaluates swelling, discoloration and degradation of materials and operation after exposure.
508.8Fungus: Exposure to fungal spores under warm, humid conditions. The test shows whether materials, coatings or contamination support fungal growth and whether surfaces, insulation or function are impaired as a result.
509.8Salt Fog / Corrosive Environments: Corrosion testing of the protection provided by coatings, finishes and enclosure materials. Since Change Notice 1 (2022) the method has been divided into three procedures; in the 2019 edition it was Method 509.7 Salt Fog.
Procedures: I Corrosion Screening · II Design Corrosion Verification · III Natural Environment
511.7Explosive Atmosphere: Operation in an ignitable fuel-air mixture. Demonstrates that the test item does not ignite the mixture or that an explosion inside the enclosure is contained.
518.2Acidic Atmosphere: Exposure to an acidic atmosphere such as found in industrial areas or near exhaust from combustion processes. Evaluates corrosion of metals and contacts and the resistance of protective coatings.

↑ Back to overview

Dynamic tests to MIL-STD-810H (513.8 to 517.3, 519.8, 522.2, 525.2 to 528.1)

Road excitation, engines, rotors, gunfire and transport impacts place mechanical loads on structures, mountings, solder joints and connectors. The dynamic methods reproduce vibration, shock, acceleration and acoustic loads – from classical profiles on a shaker to the replication of measured time histories on several exciters.

513.8Acceleration: Steady inertial loads as they occur during manoeuvres and acceleration of air and ground vehicles, as well as crash loads. Checks structural strength, mountings and operation under load.
514.8Vibration: Vibration exposure across the entire life cycle, from transport by road, rail, sea and air to operation in vehicles, aircraft and helicopters. Sine and random vibration reveal fatigue, loosening, wear and malfunctions.
515.8Acoustic Noise: High sound pressure levels as found near jet engines, in weapon bays or on external aircraft stores. Checks whether acoustic excitation fatigues structures or disturbs the function of sensitive components.
516.8Shock: Shock loads from handling, transport and service, including functional shock, transportation shock, transit drop, bench handling and crash hazard shock. Demonstrates the strength and function of the test item after impact.
517.3Pyroshock: Very short, high-frequency shock waves introduced into the structure when pyrotechnic devices such as separation bolts or cutting charges are fired. Checks the robustness of sensitive electronics such as relays, crystals and solder joints.
519.8Gunfire Shock: Repeated shock and vibration caused by firing the platform's own onboard guns. Checks the strength and function of components mounted close to the weapon.
522.2Ballistic Shock: Infrequent, very high-level shock from momentum exchange, for example when projectiles or explosive devices hit an armoured vehicle. Checks whether components mounted in the vehicle survive the shock without damage or loss of function.
525.2Time Waveform Replication: Reproduction of measured or specified field time histories on the vibration exciter. This allows non-stationary and transient loads to be simulated realistically where classical sine or random profiles fall short.
526.2Rail Impact: Coupling impacts during shunting of railcars in rail transport. Checks the strength of the test item and its tie-down; the standard specifies impact tests with actual railcars for this purpose.
527.2Multi-Exciter Test: Vibration testing with several exciters operating simultaneously, for large or long test items and for motion in more than one degree of freedom. This reproduces loads that a single shaker cannot generate.
528.1Mechanical Vibrations of Shipboard Equipment: Vibration testing of equipment installed on naval ships. Derived from MIL-STD-167, it is the only method that may be called out without prior tailoring.
Types: I Environmental · II Internally Excited

↑ Back to overview

Combined environment tests to MIL-STD-810H (520.5, 523.4)

In service, stresses rarely occur in isolation. The combined methods superimpose temperature, humidity, altitude, vibration and acoustic loads and so reveal interactions that individual tests do not show; they complement the individual methods but do not replace them.

520.5Combined Environments: Simultaneous exposure to temperature, humidity, altitude, vibration and variations in electrical power input, primarily for airborne equipment. The test reveals failures that only occur when these conditions act together.
523.4Vibro-Acoustic/Temperature: Combined acoustic, vibration and temperature loads for externally carried aircraft stores in captive carry flight, such as missiles and pods on suspension points. Demonstrates function and reliability over the mission profile.

↑ Back to overview

RTCA-DO-160G

RTCA-DO-160G

Scope of testing to RTCA DO-160G

Sections 4.0 to 26.0 of RTCA DO-160G cover the environmental and EMC tests for airborne equipment. For each section, the manufacturer selects a category that matches the installation location and aircraft type and records it on the Environmental Qualification Form. We perform each section individually or as a complete qualification sequence to your specification.

↓Climate and altitude↓Environmental resistance↓Mechanical and safety↓Power and EMC↓Lightning↓Contact

Climatic tests to RTCA DO-160G (Sections 4.0 to 6.0, 24.0)

From the heated cockpit to the unprotected wheel well, airborne equipment experiences temperatures, pressure changes and humidity that vary widely with altitude and area of operation. The climatic sections test operation and storage under these conditions; the test severity follows from the category chosen for the installation location.

Section 4.0Temperature and Altitude: Operation and storage at low and high temperatures, short-time high-temperature operation, loss of cooling, and tests at altitude, rapid decompression and overpressure. The temperature and altitude category depends on the installation location and aircraft type, for example pressurised or non-pressurised areas.
Section 5.0Temperature Variation: Cycling between low and high operating temperatures at a defined rate of change, as occurs during climb and descent. Checks operation and mechanical integrity under thermal cycling.
Section 6.0Humidity: Cyclic exposure to a warm, humid atmosphere, with categories for standard, severe and external installation locations. Evaluates corrosion, insulation behaviour and operation after exposure.
Section 24.0Icing: Ice accretion on equipment exposed to icing outside or in unheated areas, including freezing condensation. Checks whether operation and moving parts are maintained under the ice.

↑ Back to overview

Environmental resistance to RTCA DO-160G (Sections 10.0 to 14.0)

Condensation, rain, operating fluids, sand, fungi and salt-laden air attack enclosures, seals and materials. These sections demonstrate that airborne equipment remains sealed and resistant at its installation location and keeps working after exposure.

Section 10.0Waterproofness: Exposure to dripping water, spray or a continuous water stream, depending on installation location and category. Checks whether water enters the equipment and impairs its operation, for example from dripping condensation, rain or cleaning with a water jet.
Section 11.0Fluids Susceptibility: Contact with fluids used in aircraft operation, such as fuels, hydraulic fluids, lubricants, cleaning and de-icing fluids, by spraying or immersion. Evaluates the resistance of materials, seals and markings and operation after exposure.
Section 12.0Sand and Dust: Exposure to blowing dust and sand for equipment installed where particles can enter. Checks ingress into enclosures and connectors, abrasion and malfunctions caused by deposited particles.
Section 13.0Fungus Resistance: Exposure to fungal spores under warm, humid conditions. The test shows whether the materials used support fungal growth and whether this impairs operation or insulation.
Section 14.0Salt Fog: Salt fog exposure for equipment subject to a salt-laden atmosphere, for example in coastal or over-water operation. Evaluates corrosion, the protection provided by coatings and operation after exposure.

↑ Back to overview

Mechanical and safety tests to RTCA DO-160G (Sections 7.0 to 9.0, 26.0)

Engines, rotors, turbulence and landing impacts load the structure and mounting of equipment throughout its service life. Besides vibration and shock, this group includes the safety tests that rule out ignition of flammable mixtures and verify fire behaviour.

Section 7.0Operational Shocks and Crash Safety: The operational shock test reproduces shocks in normal flight operations, such as gusts, taxiing and landing; the equipment must work correctly afterwards. The crash safety test uses impulse and sustained acceleration to demonstrate that the equipment and its mounting do not break loose and become a hazard in an emergency landing.
Section 8.0Vibration: Sinusoidal and random vibration according to categories for standard, robust and high-level installation locations and for helicopters, depending on aircraft type and installation zone. Demonstrates operation during vibration and the structural integrity of mountings, connectors and solder joints.
Section 9.0Explosive Atmosphere: Testing in an ignitable fuel-air mixture for equipment installed in areas where flammable vapours may be present. Demonstrates that the equipment does not ignite the mixture through sparks or hot surfaces, or that an explosion inside the enclosure is contained.
Section 26.0Fire and Flammability: Tests the fire resistance and flammability of equipment and its non-metallic materials, depending on the installation location, for example fire zones or the cabin. Evaluates burning behaviour, flame propagation and whether the equipment withstands fire for the required duration.

↑ Back to overview

Power input and EMC to RTCA DO-160G (Sections 15.0 to 21.0, 25.0)

Aircraft power, radio and navigation systems and many units installed in a confined space place high demands on electromagnetic compatibility. These sections test behaviour at the power input, susceptibility to coupled and radiated interference and the equipment's own RF emissions; the magnetic effect on compasses is also covered.

Section 15.0Magnetic Effect: Determines the magnetic effect of the equipment on nearby compasses and magnetic sensors. The result is the minimum distance at which the equipment no longer exceeds a specified compass deflection, which defines its category.
Section 16.0Power Input: Tests behaviour on AC and DC power under normal and abnormal conditions: voltage and frequency deviations, interruptions, surges and dips, ripple and inrush current. Demonstrates that the equipment maintains the required performance or behaves in a defined manner.
Section 17.0Voltage Spike: Short voltage spikes are applied to the power leads, as caused by load switching on the aircraft power system. Demonstrates that the equipment is neither damaged nor loses its function.
Section 18.0Audio Frequency Conducted Susceptibility – Power Inputs: Tests susceptibility to audio-frequency components superimposed on the supply voltage, for example from generators and connected loads. The equipment must meet its performance specification throughout.
Section 19.0Induced Signal Susceptibility: Tests susceptibility to signals coupled into the equipment wiring from adjacent cables, via power-frequency magnetic and electric fields and switching transients. The test reproduces coupling in shared wire bundles.
Section 20.0Radio Frequency Susceptibility (Radiated and Conducted): In the conducted test, RF current is injected into cable bundles via an injection probe; in the radiated test, the equipment is exposed to electromagnetic fields in an anechoic or reverberation chamber. The category depends on the field environment at the installation location.
Section 21.0Emission of Radio Frequency Energy: Measures the conducted and radiated RF emissions of the equipment. The limits protect onboard radio, navigation and communication receivers; the category depends on the installation location and proximity to antennas.
Section 25.0Electrostatic Discharge: Electrostatic discharges are applied to points touched by personnel during operation and maintenance. Demonstrates that discharges cause no permanent damage or malfunction.

↑ Back to overview

Lightning tests to RTCA DO-160G (Sections 22.0, 23.0)

Commercial aircraft are struck by lightning regularly in service. The two lightning sections separate the indirect effects on internal wiring and electronics from the direct effects on externally mounted equipment.

Section 22.0Lightning Induced Transient Susceptibility: Reproduces the indirect effects of a lightning strike on the aircraft. Transients are applied directly to individual connector pins (pin injection) and to cable bundles, as single stroke, multiple stroke and multiple burst.
Section 23.0Lightning Direct Effects: Tests externally mounted equipment such as antennas, lights, probes and sensors for the direct effects of a lightning strike. High-voltage and high-current tests demonstrate that the part and its feedthrough conduct the lightning current without hazardous damage.

↑ Back to overview

STANAG 1307

STANAG 1307

STANAG 1307
STANAG 4234

STANAG 4234

STANAG 4234
STANAG 4235

STANAG 4235

STANAG 4235
STANAG 430

STANAG 430

STANAG 430
STANAG 4324

STANAG 4324

STANAG 4324
STANAG 4860

STANAG 4860

STANAG 4860
STANAG 4867

STANAG 4867

STANAG 4867
VG 95370

VG 95370

VG 95370
VG 95373

VG 95373

VG 95373
Ihr persönlicher Ansprechpartner bei EDAG Testing
Your Direct Contact

Questions About Our Tests?

Let’s talk about your specific testing requirements.

Get in Touch →