Details
Product information "Test Procedure - Test Ea and Guide: Shock"
This section of IEC 60068 specifies a standard procedure for determining the resistance of a test specimen to non-repetitive or repetitive shocks of a defined severity level
| Clamping surface: | up to 1.2 m x 1.2 m |
|---|---|
| Masses: | up to 300 Kg |
| Mechanical shock: | Half-sine, sawtooth, or trapezoidal waveform: 1-15 ms, up to 50g (always dependent on the combination of mass, structure, and shock requirements) |
| Norm group: | DIN EN |
| Temperature range: | -40°C to +120°C and up to 95% RH |
| Test standard: | DIN EN 60068-2-27 |
| Vibration systems: | 10 kN to 74 kN |